Article
Lf/Hf Signal Tracer
20 Measurement ranges Alternating voltage: Bandwidth: Input impedance: Measurement amplifier Output impedance: Bandwidth: Amplification: Monitor amplifier Bandwidth: -40 dB (10 my) -20 dB (100 my) 0 dB (1 V) +20 dB (10 V) +40 dB (100 V) 15 Hz to 350 kHz (-3 dB) 30 Hz to 200 kHz (-1 dB) >1 MO 600 0 see "Measurement anges" 100 (40 dB) (10 mV range, attenuator at 0 dB) 35 Hz to 21 kHz (-3 dB) Output voltage: Nominal load resistance: Nominal output power: Sine-wave generator Frequency: Output amplitude: Distortion: Output impedance: Power supply Input voltage (mains powered): Stand-by current @ 11 V: Stand-by current @ 9 V (battery powered): Maximum current consumption at nominal AF output power: 0 V to 6 Vpp (2.2 Vrms) 8 560 mW 1 kHz 0 V to 4.25 Vpp (1.5 Vrms) less thee 0.05% (2nd harmonic) max.3 lc min. 11 VDC 5 mA (St off) 18 mA (Si on) ‹0.1 RA (Si off) approx. 13 mA (Si on) 125 rnA @ 9 V (battery-powered) 125 rnA @ 8 V (mains-powered) LF/HF SIGNAL TRACER Second in our series of ...