Output Q1 of this delay circuit becomes
active after the switch-on period has
elapsed and remains so until the next cycle
is begun. Output Q2, on the other hand,
also functionsas a monostable; after its mono
period has elapsed. Q2 automatically becomes
inactive. The mono period can be set
between 1 second and 4 seconds with P2. The
power-on delay can be setaccurately between
1 second and 1 min ute with P1 and DIP
switch S1.