In most small solar power systems
using a boiler it is required that
the water circulation pump is not
switched on until the temperature
of the collector (the solar panel) exceeds
that of the water in the vessel.
Here, a two-sensor monitor is presented
that enables this condition
to be met. One sensor is fitted on
the collector, the other on the water
vessel. The control shown here has
two adjustments: one for the temperature
difference at which the pump
starts to operate, and one for the temperature
difference at which it is
switched off. Although these settings
are independent, the switch off
level must be lower than the
switch-on level. Calibration in degrees
Celcius is simple because the
gradient of the voltage at the wiper
ofthe potentiometers (orpresets) that
set the orr/off ternperatures is exactly
0.1 V °C^-1.